Flyline Modular Digital High & Low Voltage Protector (FDP)

Advanced Digital Voltage Protection Device for Complete Electrical Safety

Flyline Modular Digital high & low Voltage Protector FDP India

The Flyline Modular Digital Voltage Protector (FDP) from Murickens Group is an advanced high & low voltage protection device designed to safeguard homes, offices, and commercial establishments from voltage fluctuations, lightning surges, and unpredictable power variations. Built with advanced German technology, FDP ensures reliable protection for sensitive electrical and electronic equipment.

Applications

Key Features

Advanced Protection Against

Technical Specifications – Single Phase (FDP-1)

ModelFDP-1
Number of Poles1P
Rated VoltageAC 220V, 50Hz
Operating Voltage Range100V – 400V
Rated Current32A | 63A
Loading Capacity7 KVA | 14 KVA
Over Voltage Cut-Off230–270V Adjustable (Action: 0.01 sec)
Under Voltage Cut-Off120–210V Adjustable (Action: 0.1 sec)
Initial Start Delay15 Seconds
Adjustable Delay Time5 – 600 Seconds
Rapid Action TimeDisconnects within 1 Second
Self Power Consumption≤ 3W
Dimensions (L×W×H)84 × 52 × 75 mm
Operating Temperature-20°C to +40°C

Technical Specifications – Three Phase (FDP-3)

ModelFDP-3
Number of Poles3P
Rated VoltageAC 220V
Rated Current32A | 63A
Loading Capacity20 KVA | 40 KVA
Over Voltage Cut-Off230–270V Adjustable (Action: 0.01 sec)
Under Voltage Cut-Off120–210V Adjustable (Action: 0.1 sec)
Dimensions (L×W×H)85 × 90 × 75 mm
Self Power Consumption≤ 3W
Operating Temperature-20°C to +40°C
InstallationVertical DIN Rail Mounting
Relative Humidity≤ 85%
Altitude≤ 2000m

Protection Functions

  • Phase Sequence Disorder
  • Phase Imbalance Detection
  • Neutral Line Breakage Protection
  • Live Line Breakage Protection
  • Over Voltage Protection
  • Under Voltage Protection
  • Automatic Reset After Stabilization

User Settings & Control Functions

Single Phase & Three Phase Models

  • Voltage Display Button: Press for 10 seconds to switch between phase displays.
  • Delay Time Setting: Hold button for 10 seconds, then adjust between 5–600 seconds.
  • Under Voltage Setting: Adjustable from 120V–210V.
  • Over Voltage Setting: Adjustable from 230V–270V.
  • Fault Memory: Displays last fault voltage for 2 seconds.

Fault Indications

  • CBA Flashing: Phase Sequence Error
  • OPO: Neutral Line Loss
  • OPA / OPB / OPC: Phase Loss (A/B/C)
  • H-L Display: Phase Imbalance (>35%)
  • H / L Indicator: Over Voltage / Under Voltage in Phase A, B or C